| Oscilloscope Specification |
| Model |
PDS5022S |
PDS6062S |
PDS6062T |
PDS7102T |
| Bandwidth |
25MHz |
60MHz |
100MHz |
| Sample Rate(Real time ) |
100MS/s |
250MS/s |
500MS/s |
| Rise time |
≤14ns |
≤5.8ns |
≤3.5ns |
| Display |
7.8 inch color LCD,STN screen,
640×480 pixels |
8.0 inch color LCD,TFT screen,
640×480 pixels |
| Channel |
Dual channels+ external trigger |
| Sampling mode |
Normal sample﹑Peak detect and Average |
| Record length |
5K points on each channel |
6K points on each channel |
| Horizontal scale (s/div) |
5ns/div-100s/div step by 1-2.5-5 |
5ns/div-100s/div step by 1-2-5 |
| Vertical sensitivity |
5mV ~5V/div (at BNC input) |
| DC Gain Accuracy |
±5% |
±3% |
| Max. input voltage |
300V(DC+AC PK-PK,1MΩ input impedance,Probe
attenuation 10:1) |
400V(DC+AC
PK-PK) |
| Input impedance |
1MΩ±2%, in parallel with 20pF±3pF |
| Input coupling |
DC、AC |
DC、AC、GND |
| Vertical resolution (A/D) |
8 bits (2CH simultaneously) |
Sampling rate / relay
time accuracy |
±100ppm |
Interval(△T)accuracy
(DC~100MHz) |
Single:±(1 interval time+100ppm×reading+0.6ns) Average>16:±(1 interval
time+100ppm×reading+0.4ns) |
| Waveform storage |
4 waveforms |
| Cursor measurement |
△V and △T between cursors |
Line/field frequency
(Video) |
Support NTSC, PAL and SECAM |
| Acquisition modes |
Sample, Peak Detect and Average |
| Interpolation |
(sin x)/x |
| Displacement |
±50V(500mV-5V), ±2V(5mV-200mV) |
| Trigger type |
Edge, Video |
Edge, Video,
Alternate |
| Trigger mode |
Auto, Normal, Single |
| Trigger level |
±6 divisions from screen center |
| Automatic measurement |
Vpp,Vavg,RMS,Frequency,Period,Vmax,Vmin,Vtop,Vbase,Width,Overshoot
,Preshoot,Risetime,Falltime,+Width,-Width,+Duty,-Duty, Delay A→B 、
Delay A→B |
| Waveform math |
+, -, FFT |
Lissajou’s
figure |
Bandwidth |
25MHz |
60MHz |
60MHz |
100MHz |
| Phase difference |
±3 degrees |
| Interface |
USB Data Cable (Transfer waveform data to a PC) |
| Power supply |
100V-240V AC, 50Hz/60Hz, CATⅡ |
| Power consumption |
≤15W |
| Fuse |
1A, T grade, 250V |