PRODUCTS
    HDS Series
    HDS-N Series
    PDS Series
    PDS Series(new)
    MSO Series


   ACCESSORIES
   New Products
  

   HDS Series
OWON Classic Scopemeter -- HDS



   Models in the HDS Series
 Model  HDS1021M     HDS1022M  HDS2062M
 Bandwidth  20MHz  20MHz  60MHz
 Sample rate(Real time)  100MS/s  100MS/s  250MS/s
 Horizontal Scale(S/div)  5ns/div~100s/div,step by 1~2.5~5  5ns/div~100s/div,step by 1~2~5
 Rise time(at input,typical)  ≤17.5ns  ≤5.8ns
 Channels  Single  Dual
 Display  3.5'' color TFT display
 (320×240 pixels)
 3.8'' color TFT display
 (320×240 pixels)
 Dimension  180mm(L)x115mm(H)x40mm(W)
 Weight  455g  645g


Main Features:
1. Autoscale
2. 20 Automatic Measurements
3. 3 in 1(DSO+Multimeter+Cymometer)
4. Bandwidth: 20MHz-60MHZ
5. Support USB for data transmission to PC
6. TFT true color display
7. Replaceable li-ion battery back up (6 hours)


Application:
Design and Debug        Circuit function test
Education                         Technical training
Maintenance testing






 Oscilloscope Specification
 Model Name  HDS1021M    HDS1022M  HDS2062M
 Bandwidth  20MHz  20MHz  60MHz
 Sample Rate ( Real time )  100MS/s  100MS/s  250MS/s
 Horizontal Scale(S/div)  5ns/div~100s/div,step by 1~2.5~5  5ns/div~100s/div,step by 1~2~5
 Rise time(at input, typical)  ≤17.5ns  ≤5.8ns
 Display  3.5'' color TFT display
 (320×240 pixels)
 3.8'' color TFT display
 (320×240 pixels)
 Channels  Single  Dual
 Input impedance  1MΩ±2% in parallel with 20pF±3pF 
 Record length  Max. 6000 points on each channel
 Interpolation  (sin x)/x
 Probe attenuation factor  1X,10X,100X,1000X
 Input coupling

 DC, AC, GND

 DC, AC
 DC accuracy(Average)  Average>16:±(3% reading
 +0.05div) for △V
 Average>16:±(5% reading+0.05div) for △V
 Vertical Sensitivity  5mV/div~5V/div (at input)
 Vertical resolution (A/D)  8 bit
 Max. Input Voltage  400V (PK-PK) (DC + AC PK-PK, 1MΩ input impedance, Probe attenuation 10:1)
 Trigger Type  Edge, Video
 Trigger Mode  Auto, Normal, Single
 Trigger level  ±6 divisions from screen center
 Acquisition modes  Sample, Peak Detect and Average
 DC gain accuracy  ±3%  ±5%
 Automatic Measurement  Vpp,Vavg,RMS,Frequency,Period,Vmax,Vmin,Vtop,Vbase,Width,Overshoot,
 Preshoot,Risetime,Falltime,+Width,-Width,+Duty,-Duty, Delay A→B
 Delay A→B
 Waveform math  Unavailable  +, -, ×, ÷
 Waveform storage  4 waveforms
 Lissajou’s
 figure
 Bandwidth  Unavailable  20MHz  60MHz
 Phase difference  Unavailable  ±3 degrees
 Communication interface  USB
 Power supply  100V-240V AC, 50/60Hz
 Li-ion battery  7.4V, 6 hours operation
 
 Multimeter specifications
 Full scale reading  3 3/4 digits (Max.4000-count)  Diode  0V-1.5V
 Input Impedance  10 MΩ  On/Off measurement  <50(±30) beeping
 Capacitance  51.2nF-100uF:±(3%±3 digit)
 Voltage  VDC:400mV,4V, 400V: ±(1±1digit) Max.input:DC 1000V, VAC:4V,40V,
 400V:±(1±3digit)
 Frequency:40Hz-400Hz, Max:input:AC 750V(virtual value)
 Current  DCA:40mA, 400mA:±(1.5%±1 digit) 20A:±(3%±3digit)
 DAA:40mA±(1.5%±3digit) 400mA:±(2±1digit) 20A:±(3%±3digit)
 Impedance  400Ω:±(1%±3digit), 40Ω
 
 General specifications
 Interface  USB Data Cable (Transfer waveform data to a PC)
 Power  Supply:100V~240V AC,50/60Hz    DC input: 8.5VDC, 1500mA.     Battery: 6 hours
 Dimension  180mm x 115mm x 40mm
 Weight  455g  645g


 
oscilloscope